Low Humidity Air Dehumidifier Processing Unit for Cleanrooms

1. Eurostars air handling unit and air handler features• Cooling and heating for open office or factory production space application• Supply comfort cooling Air• basic filtration with primary filter, refined filtration optional• Built-in Microprocessor Control Console AHU with operation data display (opti

Featured Products

1. Eurostars air handling unit and air handler features
• Cooling and heating for open office or factory production space application
• Supply comfort cooling Air
• basic filtration with primary filter, refined filtration optional
• Built-in Microprocessor Control Console AHU with operation data display (optional)
• Belt driven centrifugal Fan
• Operation efficiency and energy saving
• Outstanding reliability and performance
• Configured flexibly, numerous options for customization
• HVACR and Industrial swift cooling application


2.Eurostars Air handler,air handling unit, ahu application
1) Heating
2) Cooling
3) Ventilating
4) Air-conditioning (HVAC)system
such as shopping mall, commercial center ,Hospital and operation room ,clean room , dust-free plant


3.Air handler technical data, Assembly drawing diagram and photo
Vertical Air Handling Unit(Return Air Condition-4 Rows)
ModelAir Flow  Total
Pressure
Power InputReturn Air
Cooling CapacityHeating CapacityWater Flow Water ResistanceWater inlet/outlet pipe Diameter
*1000CMHPakWkWL/minkPaDN
EST3VC433000.5518.726.153.412.732
EST4VC443000.752636.274.414.732
EST5VC453501.132.344.892.414.740
EST6VC463501.537.352.1106.819.640
EST7VC473501.543.961.312628.450
EST8VC483502.250.670.5145.229.450
EST10VC4103502.260.484172.818.650
EST12VC412400373101.7209.420.650
EST15VC415400498.6138.9282.622.565
EST18VC4184005.5118.3165339.624.565
EST21VC4214005.5139.5194.4400.230.465
EST25VC4254007.5169.5236.3486.634.380
Vertical Air Handling Unit(Return Air Condition-6 Rows)
ModelAir Flow  Total
Pressure
Power InputReturn Air
Cooling CapacityHeating CapacityWater Flow Water ResistanceWater inlet/outlet pipe Diameter
*1000CMHPakWkWL/minkPaDN
EST3VC633000.5524.331.569.616.732
EST4VC643000.7531.640.990.628.440
EST5VC653501.139.350.7112.230.440
EST6VC663501.545.659.1130.814.750
EST7VC673501.55469.9154.817.650
EST8VC683502.262.881.318021.650
EST10VC6103502.278.7101.8225.633.350
EST12VC612400394.4122.1270.630.465
EST15VC6154004119.3154.434238.265
EST18VC6184005.5143.1185410.440.265
EST21VC6214005.5167.8217.1480.641.280
EST25VC6254007.5203.6263.4583.845.180
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.

Low Humidity Air Dehumidifier Handling Unit for Clean Room
4. Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Low Humidity Air Dehumidifier Handling Unit for Clean Room
5. Components-air handling unit or air handler

Casing Panel and Insulation
• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance
• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement
• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performance
Low Humidity Air Dehumidifier Handling Unit for Clean Room
Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available
Low Humidity Air Dehumidifier Handling Unit for Clean Room
Famous Brand Fan and Motor
• Fan selection based on the air flow and air static requirement is  done by fan selection software
• ZIEHL-ABEGG brushless DC motor
• Built-in intelligent control modular
• Energy saving & High efficiency
• Less vibration & Low noise
• Maintenance-free & Long service life
• Direct driven/ belt driven, forward curve/ backward curve centrifugal fans, and EC fan is available for option
Low Humidity Air Dehumidifier Handling Unit for Clean Room
Shock Absorber
•High quality spring isolators 
•Protect the unit during transportation
•Guard lock for fan start up
•Eliminate shock and noise during operation

Cooling/ Heating Coil
•Large coil face area with low air speed
•Various anti-corossion coating for option, Electrophoresis and Heresite coating available
•Type: Copper tube with Aluminium fins (Cu/Al), GI/SUS frame
            Copper tube with Copper fins (Cu/Cu), GI/SUS frame
•Rows: 4R/6R(can be 2R+4R design)/8R (can be 4R+4R design)
Copper Tube Protection
•Every mounting hole filled up glass cement to prevent copper tube damage during transportation and operation
Low Humidity Air Dehumidifier Handling Unit for Clean Room
High efficiency filter
Filters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.

HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean room applications such as semiconductor production floor, operating theaters and critical processes.

Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.
Bag Filter is able to remove dust particles and is thrown away after use.
Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.
Low Humidity Air Dehumidifier Handling Unit for Clean Room
Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7
Low Humidity Air Dehumidifier Handling Unit for Clean Room
Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness 
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation
Low Humidity Air Dehumidifier Handling Unit for Clean Room
7.FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can.And you are warmly welcomed to visit our factory before PO.

Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines

8.Customer visit us
Low Humidity Air Dehumidifier Handling Unit for Clean Room
9.Air handling unit,air handler delivery or container loading
Low Humidity Air Dehumidifier Handling Unit for Clean Room
10.Installation instruction or installation photo, project photos
Low Humidity Air Dehumidifier Handling Unit for Clean Room


 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours